6 research outputs found

    The design of a logistic support system

    Get PDF

    De Gids sinds 1837. De geschiedenis van een algemeen-cultureel en literair tijdschrift

    Get PDF
    Contains fulltext : 104606.pdf (publisher's version ) (Open Access)208 p

    Clinical implementation of 3D printing in the construction of patient specific bolus for electron beam radiotherapy for non-melanoma skin cancer

    No full text
    Item does not contain fulltextBACKGROUND AND PURPOSE: Creating an individualized tissue equivalent material build-up (i.e. bolus) for electron beam radiation therapy is complex and highly labour-intensive. We implemented a new clinical workflow in which 3D printing technology is used to create the bolus. MATERIAL AND METHODS: A patient-specific bolus is designed in the treatment planning system (TPS) and a shell around it is created in the TPS. The shell is printed and subsequently filled with silicone rubber to make the bolus. Before clinical implementation we performed a planning study with 11 patients to evaluate the difference in tumour coverage between the designed 3D-print bolus and the clinically delivered plan with manually created bolus. For the first 15 clinical patients a second CT scan with the 3D-print bolus was performed to verify the geometrical accuracy. RESULTS: The planning study showed that the V85% of the CTV was on average 97% (3D-print) vs 88% (conventional). Geometric comparison of the 3D-print bolus to the originally contoured bolus showed a high similarity (DSC=0.89). The dose distributions on the second CT scan with the 3D print bolus in position showed only small differences in comparison to the original planning CT scan. CONCLUSIONS: The implemented workflow is feasible, patient friendly, safe, and results in high quality dose distributions. This new technique increases time efficiency

    Influence of the Integral Quality Monitor transmission detector on high energy photon beams: A multi-centre study

    No full text
    Item does not contain fulltextPURPOSE: The influence of the Integral Quality Monitor (IQM) transmission detector on photon beam properties was evaluated in a preclinical phase, using data from nine participating centres: (i) the change of beam quality (beam hardening), (ii) the influence on surface dose, and (iii) the attenuation of the IQM detector. METHODS: For 6 different nominal photon energies (4 standard, 2 FFF) and square field sizes from 1x1cm2 to 20x20cm2, the effect of IQM on beam quality was assessed from the PDD20,10 values obtained from the percentage dose depth (PDD) curves, measured with and without IQM in the beam path. The change in surface dose with/without IQM was assessed for all available energies and field sizes from 4x4cm2 to 20x20cm2. The transmission factor was calculated by means of measured absorbed dose at 10cm depth for all available energies and field sizes. RESULTS: (i) A small (0.11-0.53%) yet statistically significant beam hardening effect was observed, depending on photon beam energy. (ii) The increase in surface dose correlated with field size (p<0.01) for all photon energies except for 18MV. The change in surface dose was smaller than 3.3% in all cases except for the 20x20cm2 field and 10MV FFF beam, where it reached 8.1%. (iii) For standard beams, transmission of the IQM showed a weak dependence on the field size, and a pronounced dependence on the beam energy (0.9412 for 6MV to 0.9578 for 18MV and 0.9440 for 6MV FFF; 0.9533 for 10MV FFF). CONCLUSIONS: The effects of the IQM detector on photon beam properties were found to be small yet statistically significant. The magnitudes of changes which were found justify treating IQM either as tray factors within the treatment planning system (TPS) for a particular energy or alternatively as modified outputs for specific beam energy of linear accelerators, which eases the introduction of the IQM into clinical practice
    corecore